+91-782-7649-429

Corrosion Inhibitor

(Medium Hardness & Medium TDS)
In America


Corrosion Inhibitor (Medium Hardness & Medium TDS) is corrosion inhibitor for very high hardness and TDS waters in the cooling systems. Corrosion Inhibitor (Medium Hardness & Medium TDS) is a liquid product formulated to control the deposition of calcium scales in once through and re-circulating cooling water systems. The product contains a threshold inhibitor, which is particularly\effective for controlling the precipitation of calcium phosphate. Corrosion Inhibitor (Medium Hardness & Medium TDS) is a dispersant for suspended material such as silt and metal oxides. This dispersant action maintains the insoluble material in suspension, facilitating its removal from the system.

 

Specifications


Appearance
Clear, Pale yellow to amber colored liquid


pH
2.5 to 3.5


Flash Point
None

 

Advantages Prevents the Formation of Calcium Phosphate
Scale inhibition under severe conditions of calcium phosphate super saturation is cost effectively attainable with Corrosion Inhibitor (Medium Hardness & Medium TDS). The deposition of calcium phosphate scale from orthophosphate present in the cooling water system, either as the result of the inorganic phosphate corrosion control practice or from orthophosphate in the make-up, is effectively controlled by a threshold mechanism. Control of calcium phosphate is achieved without the need for costly pretreatment, undesirable pH depression and excessive blow down.

 

Stable in Chlorinated Water
Corrosion Inhibitor (Medium Hardness & Medium TDS) is stable in the presence of chlorine. There is on need to increase dosage during periods of Chlorinated.

 

Compliments Corrosion and Biological Control
Deposits provide media for the propagation of biological growth and cause localized corrosion of metal surfaces. Corrosion Inhibitor (Medium Hardness & Medium TDS) prevents the formation of deposits and disperses suspended solids. Cleaner surfaces deter further biological growth and assure better performance of corrosion inhibitors.

 

Method of Feeding
Corrosion Inhibitor (Medium Hardness & Medium TDS) should be fed neat at a point in the system where turbulent flow will assure good mixing. The products must not be mixed with other water treatment chemicals prior to feeding. Dosage rates will vary depending upon system parameters and water quality.

 

Storage & Handling
The product should not be stored in direct sunlight. If stored at ambient temperatures the product should be used within 24 months from the time of receipt.

 

Packing
Corrosion Inhibitor (Medium Hardness & Medium TDS) is available in 30 kgs, 50 kgs and 200 kgs.